Thermal Performance Analysis

U-Value Calculations

Professional thermal transmittance calculations for walls, floors, roofs, windows and doors. Building Regulations Part L compliance demonstrated.

From £50
BR 443 Compliant
24-48hr Turnaround

U-Value Calculation Services

Wall U-Values

Calculations for all wall constructions: cavity walls, solid walls, timber frame, SIPs, ICF, steel frame and non-standard build-ups. Part L limiting value: 0.26 W/m²K.

Floor U-Values

Ground floor U-value calculations including perimeter/area ratio effects. Suspended floors, solid slabs, beam and block. Part L limiting value: 0.18 W/m²K.

Roof U-Values

Pitched roofs (between/over rafters), flat roofs (warm/cold deck), room-in-roof constructions. Part L limiting value: 0.16 W/m²K.

Window U-Values

Window and door U-value calculations. Frame factors, glazing performance, overall Uw values. Part L limiting value: 1.6 W/m²K for windows.

Non-Standard Elements

Bespoke calculations for unusual constructions, heritage buildings, retrofit specifications and innovative building systems.

SAP Integration

U-value calculations formatted for direct input into SAP assessments. Consistent methodology ensures accurate energy modelling.

Part L 2021 U-Value Requirements

ElementLimiting U-ValueTypical Target
External Walls0.26 W/m²K0.18-0.22 W/m²K
Ground Floors0.18 W/m²K0.13-0.15 W/m²K
Roofs0.16 W/m²K0.11-0.13 W/m²K
Windows1.6 W/m²K1.2-1.4 W/m²K
Doors1.6 W/m²K1.0-1.4 W/m²K

Note: Limiting values are maximums. Achieving TFEE compliance typically requires better performance.

U-Value Calculation FAQs

What is a U-Value?

A U-value measures how effective a building element is as an insulator. It represents the rate of heat transfer through a structure, measured in W/m²K (watts per square metre per degree Kelvin). Lower U-values indicate better insulation. Building Regulations set maximum U-values for walls, floors, roofs, windows and doors.

When do I need U-Value Calculations?

U-value calculations are required for Building Regulations compliance on new builds, extensions and renovations. They're needed for SAP calculations, to demonstrate Part L compliance, for planning applications involving energy performance, and when specifying non-standard construction build-ups.

What U-Values does Part L require?

Part L 2021 sets limiting U-values: Walls 0.26 W/m²K, Floors 0.18 W/m²K, Roofs 0.16 W/m²K, Windows/Doors 1.6 W/m²K. However, achieving the Target Fabric Energy Efficiency Standard (TFEE) often requires better performance than these limiting values.

How is a U-Value calculated?

U-values are calculated by analysing each layer of a construction element—materials, thicknesses, thermal conductivities—plus surface resistances and any air gaps. We use industry-standard methods (BR 443, BS EN ISO 6946) and software to produce accurate, compliant calculations.

What information do you need?

We need detailed construction specifications: material types, thicknesses, densities where relevant, and the complete build-up from internal to external face. For windows and doors, we need frame types, glazing specifications and overall dimensions. Manufacturer data sheets are helpful.

Need U-Value Calculations?

Professional thermal performance analysis for Building Regulations compliance

Cookie & data consent

We use essential cookies so the booking engine and PayPal checkout work correctly — these cannot be switched off. Analytics and functional cookies are optional and help us improve the site. Privacy policy · Cookie policy